使用电气设备或在电源周围工作时,必须使用个体防护用品。如戴绝缘手套,穿保护性或绝缘性的围裙及鞋。此外电气成套设备的零部件使用要怎么使用呢?
Personal protective equipment must be used when using electrical equipment or working around the power supply. For example, wear insulating gloves, protective or insulating aprons and shoes. In addition, how to use the parts of the complete electrical equipment safely?
配电柜柜内的电子元件的布置要尽量远离主回路、开关电源及变压器,不得直接放置或靠近柜内其他发热元件的对流方向。
The electronic components in the distribution cabinet shall be arranged as far away from the main circuit, switching power supply and transformer as possible, and shall not be placed directly or close to the convection direction of other heating components in the cabinet.
主令操纵电器元件及整定电器元件的布置应避免由于偶然触及其手柄、按钮而误动作或动作值变动的可能性,整定装置一般在整定完成后应以双螺母锁紧并用红漆漆封,以免移动。
The arrangement of the master control electrical components and the setting electrical components shall avoid the possibility of misoperation or action value change due to accidental touch of its handle and button. Generally, the setting device shall be locked with double nuts and sealed with red paint after setting to avoid movement.
电气成套
系统或不同工作电压电路的熔断器应分开布置。
The fuses of the system or circuits with different working voltages shall be arranged separately.
熔断器、使用中易于损坏、偶尔需要调整及复位的零件,应不经拆卸其他部件便可以接近,以便于更换及调整。
Fuses and parts that are easily damaged in use and occasionally need to be adjusted and reset shall be accessible without disassembling other parts for easy replacement and adjustment.
熔断器安装位置及相互间距离应便于熔体的更换。
The installation position and distance between fuses shall facilitate the replacement of the melt.
不同电压等级的熔断器要分开布置,不能交错混合排列。
Fuses of different voltage levels shall be arranged separately and cannot be staggered and mixed.
有熔断指示器的熔断器,其指示器应装在便于观察的一侧。
For fuse with fuse indicator, the indicator shall be installed on the side convenient for observation.
瓷质熔断器在金属底板上安装时,其底座应垫软绝缘衬垫。
When the porcelain fuse is installed on the metal base plate, its base shall be padded with soft insulation gasket.
低压断路器与熔断器配合使用时,熔断器应安装在电源侧。
When low-voltage circuit breaker and fuse are used together, the fuse shall be installed on the power supply side.
强弱电端子应分开布置;当有困难时,应有明显标志并设空端子隔开或设加强绝缘的隔板。
Strong and weak current terminals shall be arranged separately; In case of difficulties, clear signs shall be provided and empty terminals shall be set for separation or partition with strengthened insulation shall be set.
此外相应的端子应有序号,端子排应便于更换且接线方便;离地高度宜大于350mm。更多相关内容就来我们网站http://www.tongyuhengcheng.com咨询吧!